Maxima/Optima Air Pump Manual

Assembly

 See appropriate parts diagram for call-out
     

  • Remove valve body screw (8) and remove entire valve module.
  • Separate diaphragm (14) from plastic valve corner plate (12) and pull away
    swing (16) with diaphragm.
  • Unscrew diaphragm bolt (15) and replace diaphragm (14). Replace bolt (15).


FOR OPTIMA ONLY

  • replace metal "noise eliminator" housing (21)
  • replace rheostat circuit (24) and plastic rheostat cover (23).
  • screw in "noise eliminator" housing screws (21).
  • Ensure alignment of air outlet (1) with case.
  • Close pump housing (2 and 3).
  • Screw bottom screws (4) into housing.