AquaClear Mini AquaCLear 150 AquaClear 200 AquaClear 300 AquaClear 500

AquaClear External Power Filter Manual

Filter Maintenance

For maximum filter operation and efficiency, regular cleaning of the filter and its parts is recommended every two weeks. Media maintenance should follow individual packaging instructions of the separate media. If the filter is left unattended for too long, the filter materials become clogged with debris. In extreme cases, the filter basket may be forced up from the filter case due to the pump pressure. This is an indication that the efficiency of the filtration is very low and that the media requires immediate rinsing or replacement.

AquaClear Filter Starting

To clean the unit unplug the filter. Remove cover. Remove filter basket and dump water remaining in case. Rinse collected debris from filter case, flow diverter, impeller and impeller well in clean lukewarm water. Soap or detergents are NOT recommended for filter maintenance.

AquaClear Filter Starting

Every three months the motor should be removed from the case and thoroughly cleaned. Remove motor by twisting it in the direction of the arrow on the motor. The motor should rotate 90o. Pull motor gently down to prevent damage to filter case or motor guide.

The impeller shaft is permanently installed. Pull impeller out of impeller well. Rinse impeller and impeller well of accumulated slime deposits.

To prevent kinked seal ring wet motor seal ring before insertion into filter case.